            Environmental Monitoring Program
            Establishing an EMP begins with identifying and documenting potential
            pathogen sources in all physical areas (including raw materials,
            storage and shipping areas) and cross-contamination vectors
            (employees, equipment, pests, etc.). These areas and vectors should
            be surveyed, controlled and when possible, eliminated. Implementing
            effective controls, including microbiological sampling of high-risk
            areas, should be part of the program. Sampling for pathogens or
            indicator microorganisms in food contact areas during production is
            also important.                                       pathogens of concern since they survive under similar physical, chemical
               Additionally, the EMP elevates the awareness of what is happening   and nutrient conditions as the pathogen
            in the plant environment and helps companies measure the efficiency   However, indicator organisms are not a substitute for pathogen
            of their pathogen-prevention program—for example, it is not only   testing. A positive result indicates possible contamination and a risk of
            critical to test for pathogens, but also for the overall effectiveness of   foodborne disease. It is recommended that samples be taken
            cleaning and sanitizing procedures. Both procedures are necessary   immediately before production starts, just after cleaning and sanitation
            and must be properly executed to reduce microorganisms to safe   have been completed when information regarding cleaning and sanitation
            levels.                                               are required. However, when sampling is conducted on surfaces
               The goal of a cleaning process is to remove completely food and   previously  exposed  to  chemical  germicide  treatment,  appropriate
            other types of soil from a surface. Since soils vary widely in   neutralizers must be incorporated into the medium to preserve viability
            composition, no single detergent is capable of removing all types. In   of the microbial cells.
            general, acid cleaners dissolve alkaline soils (minerals) and alkaline   To summarize, environmental sampling is an important tool to verify
            cleaners dissolve acid soils and food wastes. It is for this reason that   sources of contamination and adequacy of sanitation process, helping
            the employees involved must understand the nature of the soil to be   to refine the frequency and intensity of cleaning and sanitation, identify
            removed before selecting a detergent or a cleaning regime. The   hot spots, validate food safety programs, and provide an early warning
            cleaner must also match with the water properties and be compatible   of issues that may require corrective action. Overall, it provides the
            (i.e., not corrosive) with the surface characteristics on which it will be   assurance that products being manufactured are made under sanitary
            applied.                                              conditions.
               However, not only the correct choice of agent is necessary for an
            optimal result; it should be coupled with a mechanical action, an   เอกสารอ้างอิง/Reference
            appropriated contact time and correct operating temperature. As the   https://foodsafetytech.com/feature_article/mitigate-risk-importance-environmen
            combination of these parameters is characteristic to each process, it     tal-sampling-environmental-monitoring-program/
            becomes essential to verify effectiveness through sampling. Finally,
            cleaning is closely related to sanitation, because it can’t be sanitized
            what hasn’t been previously cleaned. The Association of Official
            Analytical  Chemists  defines  sanitizing  for  food  product  contact
            surfaces as a process that reduces the contamination level by
            99.999% (5 logs). Sanitation may be achieved using either heat
            (thermal treatment) or chemicals. Hot water sanitizing is commonly
            used where immersing the contact surfaces is practical (e.g., small
            parts, utensils).

            Effectiveness of ATP to Assess Environmental
            Hygiene
            The effectiveness of a plant’s sanitation practices must be verified to
            ensure that the production equipment and environment are sanitary.
            Operators employ several methods of verification, including physical
            and visual inspection, as part of ongoing environmental hygiene
            monitoring programs. Portable ATP bioluminescence systems are
            widely used to obtain immediate results about the sanitary or
            unsanitary condition of food plant surfaces.
               ATP results should be followed up with more in-depth confirmation
            testing, such as indirect indicator tests and pathogen-specific tests.
            Indirect indicator tests are based on non-pathogenic microorganisms
            (i.e., coliform, fecal coliforms or total counts) that may be naturally
            present in food or in the same environment as a pathogen. These
            indicator organisms are used to assess the overall sanitation or
            environmental condition that may indicate the presence of pathogens.
            The principal advantages of using indicator organisms in an EMP
            include:
                 •  Detection techniques are less expensive compared to those
            used for pathogens
                 •  Indicator microorganisms are present in high numbers and
            a baseline can be easily established
                 •  Indicator microorganisms are a valid representative of